Loading...
Loading...
Industrial Wastewater Canada sizes and supplies dissolved air flotation (daf) systems for plants in Burnaby, British Columbia. Local demand is driven by food & beverage, metal fabrication, biotech, electronics, discharging under Burnaby's sewer-use rules toward Fraser River / Burrard Inlet. Quote requests with flow rate and effluent type get a sized proposal.

Dissolved air flotation earns its keep in one specific situation: wastewater loaded with fats, oils, grease and suspended solids that settle poorly or not at all. That is the daily reality of food and beverage plants, dairies, meat and poultry processors and rendering operations, which is why the DAF has become the default pre-treatment technology in those sectors across Canada.
The process is the inverse of settling. A portion of clarified effluent is saturated with air under pressure and released at the tank inlet, where it forms clouds of microbubbles. The bubbles attach to solids and grease particles, float them to the surface as a stable sludge blanket, and a skimmer removes the blanket continuously. With the integrated chemical dosing and flocculation tube on our units, coagulant and polymer conditioning happens in-line ahead of the flotation zone, and removal rates run from 90 to 99 percent on TSS and FOG when the chemistry is tuned to the stream.
The economics are usually driven by surcharges rather than fines. A plant discharging over-strength effluent to a Canadian municipality pays for it, either through an industrial waste surcharge agreement in much of Ontario or through permit conditions like Metro Vancouver's Bylaw 299. Those fees scale with production and never stop. A DAF is a one-time capital cost that cuts the surcharged load at the source, and we size every unit with that payback math in view, using your actual surcharge invoice where you have one. For many food processors the system pays for itself against fees alone.
Construction is stainless steel, and the compact skid packages arrive pre-piped and pre-wired, which keeps installation to utility connections and commissioning rather than a fabrication project on your floor. A DAF also protects whatever sits downstream: a biological system runs far more stably when the grease load is removed ahead of it, and a municipality sees a plant that holds its numbers.
Sizing a DAF from a brochure is guesswork. Sizing it from data takes three inputs: your peak flow rate, a lab analysis of the effluent or at minimum a description of the process producing it, and your discharge limits. Send those and we return a sized configuration, budget price and delivery timeline for your plant, anywhere in Canada, with every proposal reviewed by a process engineer first. Commissioning includes jar testing on site to lock in the coagulant and polymer recipe, and operator training is part of the startup scope, because a DAF tuned once and understood by the people running it holds its removal rates for years.
Burnaby's industry concentrates in the Big Bend flats along the Fraser and the Still Creek corridor, some of the last close-in industrial land in Metro Vancouver. Food and beverage plants, metal fabricators, biotech firms and electronics manufacturers share those zones in a city of 249,000, and every significant discharger holds a waste discharge permit under GVS&DD Bylaw 299. Still Creek runs through the middle of it Still Creek is the detail that changes behaviour here. Still Creek—Big Bend industrial zone; GVS&DD Bylaw 299 permits. That is the regulatory backdrop for dissolved Air Flotation (DAF) Systems in Burnaby: equipment gets sized against the local limits on the route to Fraser River / Burrard Inlet, not against a national average.
Location
Burnaby, British Columbia
Population 249K
Receiving Water
Fraser River / Burrard Inlet
Pricing
Sized & quoted per project
With salmon-bearing Still Creek running straight through Burnaby's industrial corridor, wastewater diligence here goes beyond the Bylaw 299 permit, because a creek incident is public within hours. In Burnaby, the plants asking about dissolved Air Flotation (DAF) Systems are mostly in food & beverage, metal fabrication, biotech and electronics, and each of those sectors puts a different load on a treatment train. Still Creek—Big Bend industrial zone; GVS&DD Bylaw 299 permits. Direct discharge toward Fraser River / Burrard Inlet instead requires a waste discharge authorization under British Columbia's Environmental Management Act. In a city of Burnaby's size the industrial dischargers are few enough that the utility knows each one by name, which cuts both ways at permit renewal. Projects in Burnaby tend to be one-of-a-kind rather than repeat configurations, which is exactly the case where sizing from measured effluent data matters most.
Everything you need to know about our services.
Yes. Industrial Wastewater Canada sizes and supplies dissolved Air Flotation (DAF) Systems for plants across Burnaby and the surrounding region. Most local demand comes from food & beverage, metal fabrication, biotech, electronics. Send a quote request with your flow rate and effluent type and a sized proposal follows.
Still Creek—Big Bend industrial zone; GVS&DD Bylaw 299 permits. A salmon-bearing urban stream flowing directly through the industrial corridor means a spill or a cross-connection is visible within hours, in a region where stream stewardship groups are organized and vocal. Plants in the corridor invest in secondary containment, drain mapping and stormwater segregation beyond the letter of their permits because the reputational cost of a creek incident dwarfs the capital saved. Plants discharging to the municipal sewer answer to that regime; anything released directly toward Fraser River / Burrard Inlet needs a waste discharge authorization under British Columbia's Environmental Management Act. We size equipment against whichever limit governs your outfall.
From your numbers, not from the city's. We start with measured flow and effluent characterization, then check the result against Burnaby's local limits. A processor in a city of 249K with food & beverage as the dominant sector rarely has the same loading profile as its neighbours, so treatability data drives the selection.
There is no list price; every system is sized and quoted per project. The economics are local, though. On the process side the work is standard Metro Vancouver fare, DAF for food plants, oil-water separation and metals treatment for fabricators, batch neutralization for biotech, delivered into buildings where floor space is the scarcest input. Payback in Burnaby is usually calculated against those surcharge and compliance costs, and the quote spells that comparison out.
Flow, contaminants, discharge limit. An engineer replies with a sized treatment train and a quote — no obligation.