Industrial Wastewater Canada sizes and supplies oil & gas / produced water for plants in London, Ontario. Local demand is driven by food & beverage processing, agri-food, auto parts, chemicals, discharging under London's sewer-use rules toward Thames River. Quote requests with flow rate and effluent type get a sized proposal.

Oil and water separate on their own, given time. The entire discipline of oil and gas wastewater treatment exists because nobody in the industry has that time, and because the last few percent of oil refuses to leave without help. Free oil rises and skims easily. Dispersed droplets need coalescing plates or gas flotation. Emulsified oil, stabilized by production chemicals and shear from pumps, needs chemistry to break before any mechanical device can touch it. Knowing which fraction dominates your stream decides the equipment, which is why we ask for an oil-in-water analysis before we quote anything.
The applications span the value chain. Upstream, produced water from Alberta and Saskatchewan wells carries oil, solids and dissolved salts, and is treated for reinjection, disposal, or reuse in waterfloods, where oil carryover fouls injection formations. Midstream terminals and truck washouts generate slop oil and tank bottoms. Downstream, refineries run API separators as the first line, followed by dissolved gas or air flotation ahead of biological treatment. Gas plants add their own stream: amine and glycol wastes that behave nothing like produced water and should never be mixed with it.
Our equipment for this sector includes API oil water separator packages built to the API 421 gravity-separation design method, corrugated and inclined plate coalescing separators for tighter footprints, induced and dissolved gas flotation units, skimmer systems, and coalescing filter vessels for final polishing where discharge or reinjection specs demand single-digit oil concentrations. For remote batteries and early-production facilities the package arrives skid-mounted and winterized.
Alberta Energy Regulator directives, Saskatchewan disposal rules and federal offshore regulations each define oil-in-water limits differently, so we design against your specific approval rather than a generic number.
Send us the analysis, the flow range and the destination of the water, whether that is disposal well, waterflood or surface discharge. The proposal that comes back will name the separation stages, the expected outlet quality at each, and the turndown behaviour, because oilfield flows never stay at design point for long. A practical note on solids: produced sand and fines shorten the life of every separation stage, so where the well history shows sand production we put hydrocyclones or filtration ahead of the separator rather than letting the API vessel become a settling basin.
London sits at the centre of southwestern Ontario's agri-food belt, and its plants process what the surrounding counties grow: vegetables, dairy, grains and meat, alongside beverage bottlers, auto-parts makers and specialty chemical producers. The city of 422,000 discharges to the Thames River through six treatment plants, and Wastewater By-law WM-28 sets the terms for the industrial share of that flow. Agri-food seasonality is the sizing problem A London vegetable processor might run near zero flow in May and 1,500 m³/day at harvest, with BOD tracking the same curve. Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. That is the regulatory backdrop for oil & Gas / Produced Water in London: equipment gets sized against the local limits on the route to Thames River, not against a national average.
Location
London, Ontario
Population 422K
Receiving Water
Thames River
Pricing
Sized & quoted per project
London's harvest-season surges, near-zero flow in May and 1,500 m³/day in September, make equalization and staged DAF trains the core of industrial wastewater design under By-law WM-28. In London, the plants asking about oil & Gas / Produced Water are mostly in food & beverage processing, agri-food, auto parts and chemicals, and each of those sectors puts a different load on a treatment train. Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. Direct discharge toward Thames River instead requires an Environmental Compliance Approval from Ontario's Ministry of the Environment, Conservation and Parks. In a city of London's size the industrial dischargers are few enough that the utility knows each one by name, which cuts both ways at permit renewal. Projects in London tend to be one-of-a-kind rather than repeat configurations, which is exactly the case where sizing from measured effluent data matters most.
Everything you need to know about our services.
Yes. Industrial Wastewater Canada sizes and supplies oil & Gas / Produced Water for plants across London and the surrounding region. Most local demand comes from food & beverage processing, agri-food, auto parts, chemicals. Send a quote request with your flow rate and effluent type and a sized proposal follows.
Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. Sizing pretreatment for the peak wastes capital eleven months a year; sizing for the average violates the by-law every September. The designs that work here lean on equalization storage, modular DAF trains that switch on in stages, and honest conversations with the city about seasonal discharge agreements. Plants discharging to the municipal sewer answer to that regime; anything released directly toward Thames River needs an Environmental Compliance Approval from Ontario's Ministry of the Environment, Conservation and Parks. We size equipment against whichever limit governs your outfall.
From your numbers, not from the city's. We start with measured flow and effluent characterization, then check the result against London's local limits. A processor in a city of 422K with food & beverage processing as the dominant sector rarely has the same loading profile as its neighbours, so treatability data drives the selection.
There is no list price; every system is sized and quoted per project. The economics are local, though. Auto-parts and chemical plants bring steadier flows with oil, metals and pH issues instead. The common thread is the Thames, a warm, slow river whose limited assimilative capacity keeps London's by-law enforcement consistent. Payback in London is usually calculated against those surcharge and compliance costs, and the quote spells that comparison out.