Industrial Wastewater Canada sizes and supplies membrane bioreactor (mbr) systems for plants in London, Ontario. Local demand is driven by food & beverage processing, agri-food, auto parts, chemicals, discharging under London's sewer-use rules toward Thames River. Quote requests with flow rate and effluent type get a sized proposal.

A membrane bioreactor combines two unit processes in one tank: biological treatment that consumes dissolved organics, and ultrafiltration membranes that physically retain the biomass instead of relying on a clarifier to settle it. The result is effluent that is essentially free of suspended solids and most bacteria, clean enough for reuse in washdown or cooling service, or for discharge to sensitive receiving waters.
Because the membranes decouple solids retention from settling, an MBR runs at much higher biomass concentrations than conventional activated sludge. That is where the footprint advantage comes from: 50 to 70 percent smaller than a conventional plant treating the same load, which matters when the only available space is inside an existing building. It also explains the stability. High biomass inventory absorbs the load swings that industrial production schedules create, so performance holds through washdown peaks and weekend shutdowns. The strongest fits are food and beverage plants, landfill leachate and high-BOD process water, and any site where reuse or a strict discharge limit justifies the premium.
We supply MBR packages with submerged flat-sheet or hollow-fibre membranes, automated CIP cleaning systems, and the instrumentation to run unattended between operator rounds. The Canadian search interest is real; the membrane bioreactor cluster draws about 1,000 searches a month, the highest of any equipment family we track. But interest is not a specification, so here is the honest trade-off we walk every buyer through. Capital cost is higher than MBBR or conventional treatment because of the membrane modules. Energy use is higher too, since air scouring to keep membranes clean is a significant load. Membranes foul, need routine relaxation and periodic chemical cleaning, and are replaced roughly once a decade, a cost that belongs in your budget from day one. Fats, oils and abrasive solids shorten membrane life, so pre-treatment with fine screening at 1 to 3 mm and FOG removal ahead of the tank is not optional.
Where footprint is tight, limits are strict, or reuse pays back the premium, an MBR is the right call. Where none of those apply, we will usually recommend MBBR or conventional treatment instead. Send your flow rate, a recent lab analysis and your discharge destination, and a process engineer returns a sized configuration, budget price and delivery timeline for your site, anywhere in Canada. Where the effluent analysis is incomplete, we will specify the sampling program first, because an MBR sized on guesswork wastes exactly the capital premium that makes the technology worth buying.
London sits at the centre of southwestern Ontario's agri-food belt, and its plants process what the surrounding counties grow: vegetables, dairy, grains and meat, alongside beverage bottlers, auto-parts makers and specialty chemical producers. The city of 422,000 discharges to the Thames River through six treatment plants, and Wastewater By-law WM-28 sets the terms for the industrial share of that flow. Agri-food seasonality is the sizing problem A London vegetable processor might run near zero flow in May and 1,500 m³/day at harvest, with BOD tracking the same curve. Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. That is the regulatory backdrop for membrane Bioreactor (MBR) Systems in London: equipment gets sized against the local limits on the route to Thames River, not against a national average.
Location
London, Ontario
Population 422K
Receiving Water
Thames River
Pricing
Sized & quoted per project
London's harvest-season surges, near-zero flow in May and 1,500 m³/day in September, make equalization and staged DAF trains the core of industrial wastewater design under By-law WM-28. In London, the plants asking about membrane Bioreactor (MBR) Systems are mostly in food & beverage processing, agri-food, auto parts and chemicals, and each of those sectors puts a different load on a treatment train. Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. Direct discharge toward Thames River instead requires an Environmental Compliance Approval from Ontario's Ministry of the Environment, Conservation and Parks. In a city of London's size the industrial dischargers are few enough that the utility knows each one by name, which cuts both ways at permit renewal. Projects in London tend to be one-of-a-kind rather than repeat configurations, which is exactly the case where sizing from measured effluent data matters most.
Everything you need to know about our services.
Yes. Industrial Wastewater Canada sizes and supplies membrane Bioreactor (MBR) Systems for plants across London and the surrounding region. Most local demand comes from food & beverage processing, agri-food, auto parts, chemicals. Send a quote request with your flow rate and effluent type and a sized proposal follows.
Centre of southwestern Ontario agri-food belt; City of London Wastewater By-law WM-28. Sizing pretreatment for the peak wastes capital eleven months a year; sizing for the average violates the by-law every September. The designs that work here lean on equalization storage, modular DAF trains that switch on in stages, and honest conversations with the city about seasonal discharge agreements. Plants discharging to the municipal sewer answer to that regime; anything released directly toward Thames River needs an Environmental Compliance Approval from Ontario's Ministry of the Environment, Conservation and Parks. We size equipment against whichever limit governs your outfall.
From your numbers, not from the city's. We start with measured flow and effluent characterization, then check the result against London's local limits. A processor in a city of 422K with food & beverage processing as the dominant sector rarely has the same loading profile as its neighbours, so treatability data drives the selection.
There is no list price; every system is sized and quoted per project. The economics are local, though. Auto-parts and chemical plants bring steadier flows with oil, metals and pH issues instead. The common thread is the Thames, a warm, slow river whose limited assimilative capacity keeps London's by-law enforcement consistent. Payback in London is usually calculated against those surcharge and compliance costs, and the quote spells that comparison out.
Flow, contaminants, discharge limit. An engineer replies with a sized treatment train and a quote — no obligation.