Loading...
Loading...
Industrial Wastewater Canada sizes and supplies lamella clarifiers for plants in Calgary, Alberta. Local demand is driven by oil & gas services, food processing, chemicals, logistics, discharging under Calgary's sewer-use rules toward Bow River. Quote requests with flow rate and effluent type get a sized proposal.

A lamella clarifier does what a conventional circular clarifier does, in about a tenth of the floor space. The trick is geometry. Instead of one large settling surface, the vessel stacks dozens of inclined plates, and each plate acts as its own shallow settling zone. Projected settling area multiplies while the tank stays compact, which is how a unit the size of a shipping container replaces a settling basin, cutting footprint by up to 90 percent.
Solids-laden water enters below the plate pack and rises between the plates. Particles settle onto the plate surfaces within a short vertical distance, slide down the incline into a collection hopper, and clarified water exits at the top through distribution orifices that keep flow even across the pack. There are no moving parts in the settling zone, so wear items are few and maintenance stays on the pumps and dosing systems where it belongs. The integrated sludge thickening hopper concentrates the underflow before it goes to dewatering, which shrinks the load on whatever press or centrifuge follows.
The applications where lamella clarifiers dominate are the ones where solids are the whole problem: mining and mineral processing water, construction and groundwater dewatering, metal finishing effluent after chemical precipitation, and industrial process water carrying grit or floc. Where the raw stream will not settle on its own, we add integrated flash-mix and flocculation stages ahead of the plate pack, so coagulant, polymer and settling happen in one skid. Vessel construction is 304 or 316 stainless or coated carbon steel, matched to the chemistry of your stream rather than defaulted.
Sizing a lamella clarifier is a solids problem, not a flow problem. Two streams at the same flow rate can need very different plate areas depending on particle size, floc strength and solids loading, which is why we ask for a lab analysis or at least a jar test before quoting, and why the 110 monthly Canadian searches for this equipment so often come from engineers replacing an undersized unit bought on flow rate alone. Send your flow, your solids data and your discharge destination, and we return a sized configuration, budget price and delivery timeline for your site, anywhere in Canada. Every proposal is reviewed by a process engineer first, and pilot units can be arranged where treatability is genuinely uncertain. Plate packs are removable for inspection and washing without dismantling the vessel, and replacement packs remain available for the life of the unit, so recovery from an upset upstream is a cleaning day rather than a capital request.
Calgary sits at the junction of two wastewater markets. Inside city limits, well over a million people and a growing base of food processors, chemical blenders and logistics operators discharge under Wastewater Bylaw 14M2012, with the Bow River as the receiving water. Outside the city, the surrounding basin runs on produced water and work-camp utilities, a market with no municipal sewer at all. City of Calgary Wastewater Bylaw 14M2012; large produced-water and camp wastewater market in surrounding basin. That is the regulatory backdrop for lamella Clarifiers in Calgary: equipment gets sized against the local limits on the route to Bow River, not against a national average.
Location
Calgary, Alberta
Population 1,307K
Receiving Water
Bow River
Pricing
Sized & quoted per project
Calgary plants answer to Bylaw 14M2012 and a trout river with no assimilative capacity to spare, while an hour away the produced-water market needs wastewater treatment skids that run unattended at −30 °C. In Calgary, the plants asking about lamella Clarifiers are mostly in oil & gas services, food processing, chemicals and logistics, and each of those sectors puts a different load on a treatment train. City of Calgary Wastewater Bylaw 14M2012; large produced-water and camp wastewater market in surrounding basin. Direct discharge toward Bow River instead requires an approval under Alberta's Environmental Protection and Enhancement Act. A metro of Calgary's size runs enough industrial flow that the municipal plant polices its intake closely, and surcharge invoices arrive on schedule. We quote lamella Clarifiers in Calgary often, and the sizing conversation usually starts from a surcharge bill or a compliance letter rather than from a catalogue.
Everything you need to know about our services.
Yes. Industrial Wastewater Canada sizes and supplies lamella Clarifiers for plants across Calgary and the surrounding region. Most local demand comes from oil & gas services, food processing, chemicals, logistics. Send a quote request with your flow rate and effluent type and a sized proposal follows.
City of Calgary Wastewater Bylaw 14M2012; large produced-water and camp wastewater market in surrounding basin. Bow River limits meet oilfield volumes The Bow is a cold, clear trout river with little assimilative capacity to spare, so the city keeps its bylaw limits tight and its sampling frequent. Meanwhile an oil and gas service company an hour away may need to treat 500 m³/day of produced water to reuse or disposal standards with nothing but a skid and a generator. Plants discharging to the municipal sewer answer to that regime; anything released directly toward Bow River needs an approval under Alberta's Environmental Protection and Enhancement Act. We size equipment against whichever limit governs your outfall.
From your numbers, not from the city's. We start with measured flow and effluent characterization, then check the result against Calgary's local limits. A processor in a city of 1,307K with oil & gas services as the dominant sector rarely has the same loading profile as its neighbours, so treatability data drives the selection.
There is no list price; every system is sized and quoted per project. The economics are local, though. We design for both ends: sewer-compliance pretreatment for plants inside Calgary, and self-contained packaged systems for camps and well sites where winter operation at −30 °C is a design requirement, not an edge case. Payback in Calgary is usually calculated against those surcharge and compliance costs, and the quote spells that comparison out.
Flow, contaminants, discharge limit. An engineer replies with a sized treatment train and a quote — no obligation.